Design-A-Bearing -

PUMP BEARING Imperial CALCULATOR

Input Your DataYour Data Input
Housing diameter
inches
Shaft diameter
inches
Bearing Length
inches
Press fit?
Maximum operating temp
°F
Minimum operating temp
°F
Total mass supported
lbs
Number of bearings supporting total mass
Rotation
RPM
   Results updating
Your Results
OD
ID
Wall thickness
Loading P
Shaft surface speed V
PV
Expansion gap
Interference fit
Bore closure
Additional clearance
Assembled clearance
Fitted inside diameter
Press fit force
OD after cooling with dry ice
Thin-walled bearing. Please contact us.
RESULTS SUMMARY - generated on 01/05/2024
YOUR BEARING DIAGRAM
 
(not to scale)
Size adjustment for various machining temperatures
Bearing temp OD inches Wall thickness
40-50 °F
50-60 °F
60-70 °F
Bearing temp OD inches Wall thickness
70-85 °F
85-95 °F
95-105 °F
NB. When machining please control wall thickness and outer diameter
Housing =
Shaft =
Maximum operating temp =
°F
Minimum operating temp =
°F
Share Your Results With Us

    Name
    Email
    CC
    Tel
    Country